
IndustrialandCommercialHVAC.
Design, installation and maintenance of industrial HVAC systems for logistics warehouses, process rooms, pharmaceutical environments and production centres, with RITE and F-Gas compliance guaranteed.
HVACengineeringwith+25yearsoftrackrecord.
At Isofred we design industrial HVAC systems that precisely control temperature, humidity and air quality in the most demanding environments.
We work with low-GWP refrigerants under RITE and F-Gas regulations to guarantee energy efficiency, operational comfort and production continuity.
| Parámetros | Capacidad |
|---|---|
| Temperature | −10 °C to +50 °C |
| Refrigerants | R32, R290, R1234ze, A2L |
| Capacity | 5 kW up to +500 kW per project |
| Compliance | RITE 2007, F-Gas 2024/573, EN 378 |
TypesofHVACinstallations.
Warehouses and Logistics Centres
Climate control for large volumes with air handling units, heat recovery and even distribution across the whole floor area.
Process and Production Rooms
Precise temperature and relative humidity control for work areas with high thermal loads, hygiene requirements or sensitive production processes.
Cleanrooms and GMP
Technical climate control for pharmaceutical and food environments with HEPA filtration, laminar flow and strict GMP compliance.
Free Cooling and Heat Recovery
Integration of outdoor-air systems and enthalpy recovery to cut energy consumption by up to 40%.
Industrial VRF / VRV Systems
High-performance multi-split solutions for complex industrial buildings with multiple zones and individual control.
Need a custom project?
Request a technical studyDoesyourHVACcomplywithRITEandF-Gas?
The F-Gas Regulation 2024/573 will phase out R410A (GWP 2,088) before 2030. Existing facilities running this refrigerant will need conversion. We have been installing low-impact refrigerants for over 10 years.
R32 for most VRF applications. R290 (propane) for compact systems. R1234ze for technically demanding projects.
Request a conversion studyR32: Transition from R410A
GWP 675. Up to −30% refrigerant charge. Compatible with the new equipment range. Preferred solution for VRF/VRV and industrial splits
R290 (Propane): Natural Refrigerant
GWP = 3. High energy efficiency. Ideal for compact equipment and self-contained units. F-Gas exempt
A2L: R32 and low-flammability blends
Reduced GWP. R32, R454B, R455A. Transition solution towards natural refrigerants. F-Gas 2024/573 compliant. For applications where R290 is not technically viable.
Engineeringanddeliveryfromstarttofinish.
We deliver every phase of the HVAC project with our own team, from the thermal audit to commissioning. That allows us to guarantee operational performance and meet the most demanding deadlines.
Engineering and installation work in direct coordination so that every design detail is executed with precision, guaranteeing energy efficiency, regulatory compliance and operational comfort.
Request a technical studyEngineering and technical design
In-house engineering department and technical office specialised in industrial HVAC and air quality.
- Thermal load calculation and hygrothermal balance
- Design compliant with RITE 2007 and current regulations
- Equipment selection focused on energy efficiency (A+++)
- Complete technical documentation and facility licensing
- Integration with BMS and centralised control systems
Installation and infrastructure deployment
We deliver industrial HVAC installations with our own team, integrating high-efficiency, low-impact technologies.
- Industrial air handling units (AHUs)
- VRF/VRV multi-split systems
- Fan coils and terminal units
- Air and water free cooling
- Enthalpy recovery units
- HEPA filtration and air quality control
- BMS automation and control
Ourprocess.
Thermal audit
We analyse thermal loads, infiltration and process requirements to define the optimal HVAC solution.
HVAC design
Complete executive project: equipment, duct networks, schematics and RITE and F-Gas documentation.
Installation and commissioning
Delivered with our own team. Performance testing, calibration and certified handover.
Maintenance and follow-up
Preventive contract, RITE inspections, F-Gas refrigerant control and urgent technical service to guarantee operational continuity.
RealindustrialHVACprojects

Palau de Gel de Vielha - Ice Rink
Sports facility in the Val d'Aran, with a 1,456 m² ice rink seating 630 spectators. Refrigeration plant to maintain the ice surface year-round.

Vall Companys - Office Air Conditioning
Vall Companys is one of Spain's largest agri-food groups. Natural-refrigerant air conditioning for 1,500 m² of corporate offices adjoining its plant in Almenar (Lleida).

Symrise Pet Food - Air Conditioning and Process Cooling
Spanish subsidiary of Symrise, a German multinational with more than 30 pet food manufacturing plants worldwide. Rooftop chillers, thermal plant and inertia tanks.
NeedanindustrialHVACinstallation?
Our technical team analyses your project with no obligation. Thermal audit, installation and commissioning with RITE and F-Gas compliance guaranteed.










